57 MTS_OW100_IFU-orthogold100-US-K182682_A
7 Technical, Electrical, & EMC
7.1 Electrical and EMC
In accordance with 60601-2-36:2016 the OW100
®
is designed not to display any
false energy levels and not to release any acoustic waves unintentionally.
Electronic medical equipment is subject to special precautionary measures regarding
EMC (Electrical Magnetic Compatibility). They must be installed and used in
accordance with EMC regulations as detailed below.
The OW100
®
is intended for use in an environment indicated below. Ensure the OW100
®
is operated in such an environment. The manufacturer explanations are contained in
Tables Table 2, Table 3, Table 4 and Table 5.
Table 2 Recommended safety distances between Mobile HF Telecommunication Devices and the OW100
®
Recommended separation distances between portable and mobile RF communications equipment
and the OW100
®
The OW100
®
is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the OW100
®
can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and
the OW100
®
as recommended below, according to the maximum output power of the
communications equipment.
Rated maximum output power
of transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz 80 MHz
d = 1,2√P
80 MHz 800 MHz
d = 1,2√P
800 MHz 2.7 GHz
d = 2,3√P
0.01
0.12
0.12
0.23
0.1
0.37
0.37
0.74
1
1.2
1.2
2.3
10
3.7
3.7
7.4
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 :These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems OrthoGold100 OW100-US and is the answer not in the manual?

MTS Systems OrthoGold100 OW100-US Specifications

General IconGeneral
BrandMTS Systems
ModelOrthoGold100 OW100-US
CategoryMedical Equipment
LanguageEnglish

Related product manuals