EasyManua.ls Logo

MTU 16 V 4000 C21 - Page 66

MTU 16 V 4000 C21
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Flashi
ng
code
PID SID FMI Description Maintenance tasks
77 252 10 Clock module with irregular
alteration speed.
Contact Service.
77 252 13 Clock module faulty. Contact Service.
77 354 0 Relative air humidity above
range (version 33.0 or lat‐
er).
Contact Service.
77 354 1 Relative air humidity under
range (version 33.0 or lat‐
er).
Contact Service.
77 446 0 Cylinder head temperature
above range (version 33.0
or later).
Contact Service.
77 151 11 Maintenance display lamp,
faulty / service interval ex‐
ceeded (version 32.0 or lat‐
er).
Contact Service.
78 86 14 Self-adaptive speed control
faulty (version 27.0 or later).
Contact Service.
81 98 3 Oil level sensor, input volt‐
age too high.
Contact Service.
81 101 3 Crankcase pressure sen‐
sor, input voltage too high.
Contact Service.
81 153 3 Crankcase pressure, input
voltage too high (version
27.0 or later).
Contact Service.
81 164 3 Injection control pressure
sensor, input voltage too
high.
Contact Service.
81 173 3 Exhaust temperature sen‐
sor, input voltage too high.
Contact Service.
81 411 3 EGR OPD, circuit defec‐
tive / high (version 33.0 or
later).
Contact Service.
81 412 3 EGR temperature too high
(version 33.0 or later).
Contact Service.
81 129 3 Exhaust duct temperature
1, sensor voltage too high
(version 32.0 or later).
Contact Service.
81 130 3 Exhaust duct temperature
2, sensor voltage too high
(version 32.0 or later).
Contact Service.
81 131 3 Exhaust duct temperature
3, sensor voltage too high
(version 32.0 or later).
Contact Service.
81 132 3 Exhaust duct temperature
4, sensor voltage too high
(version 32.0 or later).
Contact Service.
66 | Troubleshooting | MS150049/02E 2012-11
TIM-ID: 0000003162 - 002

Table of Contents