EasyManua.ls Logo

MTU C13 - Page 74

MTU C13
163 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault code No. Full designation Meaning Action
Related
parameter
No.
415 LO P-Coolant Intercooler
Alarm configuration limit val-
ue 1; Preliminary warning:
Coolant pressure in inter-
cooler too low.
Top up coolant
(→ Page 135).
2.0107.92
1
416 SS P-Coolant Intercooler
Alarm configuration limit val-
ue 2; Main warning: Coolant
pressure in intercooler too
low. engine shutdown.
Top up coolant
(→ Page 135).
2.0107.92
2
417
SD Water Level Fuel
Prefilter
SD alarm configuration; Sen-
sor for water level in fuel pre-
filter faulty; short circuit or
wire break.
Check sensor and
cabling, replace as
necessary.Error
cleared after re-
starting the engine.
1.8004.59
4
420 L1 Aux 1
Alarm configuration limit val-
ue 1; Input signal of Aux 1
has exceeded/not attained
limit value 1, depending on
configuration.
Determine cause of
limit value violation
and rectify fault.
2.0160.92
1
421 L2 Aux 1
Alarm configuration limit val-
ue 1; Input signal of Aux 1
has exceeded/not attained
limit value 2, depending on
configuration.
Determine cause of
limit value violation
and rectify fault.
2.0160.92
2
428 L1 T-Aux 1
Alarm configuration limit val-
ue 1; Preliminary warning:
Temperature signal of Aux 1
has exceeded / not attained
limit value 1, depending on
configuration.
Determine cause of
limit value violation
and rectify fault.
2.0130.92
1
440 L1 P-Aux 1
Alarm configuration limit val-
ue 1; Preliminary warning:
Pressure signal of Aux 1 has
exceeded / not attained limit
value 1, depending on config-
uration.
Determine cause of
limit value violation
and rectify fault.
2.0110.92
1
442 L2 P-Aux 1
Alarm configuration limit val-
ue 2; Preliminary warning:
Pressure signal of Aux 1 has
exceeded / not attained limit
value 2, depending on config-
uration.
Determine cause of
limit value violation
and rectify fault.
2.0110.93
1
444 SD U-PDU
SD alarm configuration; In-
jector power stage sensor
defect; Internal fault in
ECU7.
Replace ADEC (ECU
7).
1.8004.57
8
445 SD P-Ambient Air
SD alarm configuration; Am-
bient air pressure sensor
faulty. Replace ECU.
1.8004.58
0
448 HI P-Charge Air
Alarm configuration limit val-
ue 1; Preliminary warning:
Charge-air pressure too high. Contact Service.
2.0103.93
1
74 | Troubleshooting | M015695/03E 2013-03