Chapter 13 – SMTP Client
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 144
Setup and Configuration Prerequisites
The following details are mandatory for configuration and have to be validated before sending an email:
Host Interaction Mode enabled to restrict Telnet-Dialout and PPP.
Command: set serial <s0> host-interaction-mode enable
Set SMTP server name or IP address of maximum length 64 characters.
Command: set send-mail smtp-server-name <ipaddress/servername>
Set SMTP server port.
Command: set send-mail smtp-server-port <25>
Set Host name of maximum length 64 characters.
Command: set send-mail host-name <hostname>
Set From address identity of maximum length 64 characters.
Command: set send-mail from-address-identity <hostnameidentity>
Set From address of maximum length 64 characters.
Command: set send-mail from-address <email-Id>
Notes: 1. The send-mail command prompts for the ERROR message if any of the above details
are not configured or not valid.
2. The following configuration suggestions are optional:
Set reply-to address of maximum length 64 characters. By default the server takes
the from address as the reply-to-address.
If this is configured, this address is taken as the reply to address.
set send-mail reply-to-address <email-ID>