EasyManua.ls Logo

Multitech MultiConnect - Page 40

Multitech MultiConnect
181 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 40
Serial Commands – Setup
Command Syntax set serial [s0/s1] stop-bits <1/1.5/2>
Description
Sets the stop bits.
Default Value
1
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 stop-bits <1/1.5/2>
Type ‘set serial s0/s1 stop-bits ?’ for more information”
2. Invalid stop-bit setting
“ERROR: Stop-bit supported : [1, 1.5, 2]
Type ‘set serial s0/s1 stop-bits ?’ for more information”
Serial Commands – Show
Command Syntax show serial [s0/s1] chat-script
Description Displays the Expect and Send sequence for the serial port S0 or S1.
Default Value
NA
Success
OK
Error
1. Too few arguments
Possible value(s) are
statistics modem-configuration
configuration chat-script
Command Syntax show serial [s0/s1] configuration
Description
Displays serial S0/S1 configuration.
Default Value
-
Success
OK
Error 1. Too few arguments
Possible value(s) are
statistics modem-configuration
configuration chat-script
Command Syntax show serial [s0/s1] modem-configuration
Description
Displays the modem-related configuration for serial port S0 or S1.
Default Value
NA
Success
OK
Error 1. Too few arguments
Possible value(s) are
statistics modem-configuration
configuration chat-script

Table of Contents