Operation
Packing products
38 03.06.2014
¾ Gas flushing option: Pull the pouch opening over the gas nozzles
so that the inert gas flows into the film pouch.
¾ Pull the pouch neck flat on the sealing bar.
The pouch neck lies on the sealing bar without creases.
NOTICE Danger of material damage!
Penetration by foreign matter (e.g. liquids, product residue, foreign
bodies) will damage the vacuum pump.
Damage can cause faults in the machine, which in turn can result in
reject packs.
¾ Cancel the evacuation process immediately if foreign matter is
sucked in.
¾ Change the oil in the vacuum pump.
¾ Close and press down the chamber lid.
The processes in the machine run automatically.
The chamber lid opens automatically if it is not locked.