Operation
Select and set process
44 03.06.2014
¾ Call up the "gas flushing" menu (Optional).
¾ Switch on On/off gas flushing.
¾ Set Distribution time.
¾ Set Rinse time.
¾ Press <Gas flushing> key briefly and set value for Gas flushing
pressure.
4.9.2 To set MCV process
¾ Press <Evacuation> key briefly and enter value for Evacuation
pressure.
Info
Do not set an Evacuation pressure value in Automatic.
¾ Press <Evacuation> key briefly again and set the value for Post-
evacuation time to 0 s.
¾ Call up the "evacuation" menu.
¾ Set the value for Distribution time to 0 s.
¾ Select MCV process.
¾ Set MCV threshold.
¾ Set MCV duration.
¾ Call up the "gas flushing" menu (Optional).
¾ Switch off Gas flushing On/Off.
¾ Call up the "sealing" menu.
¾ Switch off Sealing On/Off.
4.10 Setting the sealing
¾ Call up the "sealing" menu.
¾ Switch on On/off sealing.
¾ Set Delayed ventilation.
¾ Set Cooling down.
¾ Press <Sealing> key briefly and set value for Sealing time.
4.11 Entering basic settings
¾ Call up the "basic settings" menu.
¾ Set Fill diaphragm.