EasyManua.ls Logo

multivac C200 - Entire Machine - Alkaline Cleaning and Disinfection; Vacuum Pump - Checking Oil Level, Topping up; Entire Machine - Acidic Cleaning and Disinfection; Connections - Visual Inspection

multivac C200
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
Maintenance recommendation
60 03.06.2014
¾ If necessary, replace the sealing bar, see Section 7.3 "RE-
PLACE THE SEALING BAR".
¾ Check the counter-pressure bar for damage.
¾ If necessary, repair the counter-pressure bar, see Section 7.4
"REPAIR COUNTER-PRESSURE BAR".
7.2.4 Entire machine - Alkaline cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.5 Vacuum pump - Checking oil level, topping up
¾ Check the oil level on the oil sight glass.
¾ If water is present in the oil, change the oil in the vacuum
pump, see Section 7.5 "CHANGE THE OIL IN THE VACUUM PUMP".
¾ If necessary, refill oil, see Section 7.5.2 "FILLING THE VACUUM
PUMP WITH OIL.".
7.2.6 Entire machine - Acidic cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.7 Connections - Visual inspection
¾ Disconnect the machine from the mains electricity.
¾ Check power cable for damage.
¾ If present, check that the supply line for inert gas is fitted tightly
and undamaged.
7.2.8 Vacuum system - Check
¾ Perform a vacuum test, see Section 7.8 "PERFORMING THE VAC-
UUM TEST".
7.2.9 Vacuum pump - Oil change
¾ Change the oil in the vacuum pump, see Section 7.5 "CHANGE THE
OIL IN THE VACUUM PUMP".

Table of Contents