Maintenance
Maintenance recommendation
03.06.2014 61
7.2.10 Vacuum pump - Exchanging the air de-oiling ele-
ment
¾ Change the air de-oiling element, see Section 7.6 "CHANGE THE
AIR DE-OILING ELEMENT".
7.2.11 Entire machine - Check the age
¾ Read the year of manufacture on the type plate.
¾ If the machine is older than 19 years:
¾ Shut down the machine.
¾ Have the safety functions checked by MULTIVAC Service.
7.3 Replace the sealing bar
7.3.1 Remove the sealing bar
¾ Switch off the machine.
¾ Disconnect the machine from the mains electricity.
¾ Open the chamber lid.
¾ Let the sealing bar cool down.
¾ Pull out the sealing bar.
7.3.2 Install the sealing bar
¾ Disconnect the machine from the mains electricity.
¾ Install the sealing bar on the carriers.