Cleaning
Notes on cleaning
50 03.06.2014
The temperature of the water must NOT exceed 60 °C (140 °F).
Only rinse off with water of drinking quality.
6.1.3 Instructions on the handling of cleansers
WARNING
Chemical burn hazard!
Acidic cleansers are caustic. Caustic effects are NOT noticed im-
mediately.
Contact with the skin can cause burns.
¾ Wear the prescribed personal protective equipment when han-
dling cleansers.
¾ Observe the manufacturer's instructions.
For type of cleanser, refer to the "Care products table".
Always follow the instructions for use from the cleanser manufac-
turer.
The quantity of cleanser is not the decisive factor for successful
cleaning.
Applying amounts in excess of the proper dosage does not im-
prove or accelerate cleaning efficiency, but only hinders the re-
quired rinsing off of the cleanser.
Dried cleanser residues make cleaning more difficult and pro-
longed.
Even the smallest residues can inhibit the effect of the disinfec-
tion.
Check by measuring the pH factor of the post-rinsing water.
Regular checks of cleaning (i.e. by contact tests) reduce the risk of
product contamination.
Insufficient cleaning cannot be compensated for by doubling the
concentration of the disinfectants.
6.1.4 Instructions on the handling of disinfectants
Incorrect use of disinfectant can contaminate the product with chemi-
cals or decrease the effectiveness of disinfection. This can pose seri-
ous health hazards for consumers.
Always follow the instructions for use from the disinfectant manu-
facturer.
Only rinse or wipe off after disinfection, if this is required by the
disinfectant manufacturer.
Always observe the applicable hygiene regulations.