Troubleshooting
74 03.06.2014
8 Troubleshooting
WARNING
Injury hazard!
Ignorance of proper machine handling is very dangerous.
Improper handling can lead to serious injuries.
For all service and repair work:
¾ Make sure you observe the safety instructions and accident
prevention regulations.
¾ Disconnect the unit's power supply from the mains electricity.
¾ Only qualified electricians are permitted to work on electrical
modules.
¾ Service and repair work should be carried out by authorised
technicians only.
8.1 Malfunctions with diagnostic message
Symptom Cause Solution
Vacuum pump does not
switch off.
Notify the service. 67
Ventilation valve does not
open.
Notify the service.
No gas available or near end. Connect inert gas or ensure
that there is sufficient gas
supply (e.g. change gas bot-
tle).
Stop valve for the gas supply
is closed.
Open the stop valve for the
gas supply.
Gas hose has a kink in it. Remove the kink in the gas
hose.
Value for the gas flushing
pressure is set such that it
cannot be reached.
Correct the value for Gas
flushing pressure.
The vacuum sensor is incor-
rectly calibrated.
Notify the service.
Vacuum sensor is defective. Notify the service.
68
Gas valve does not open. Notify the service.
69 Value for the Evacuation
pressure is set so low that it
cannot be reached.
Correct the value for Evacua-
tion pressure.