Troubleshooting
Malfunctions with diagnostic message
03.06.2014 75
Symptom Cause Solution
Vacuum hose between the
chamber and the vacuum
sensor is clogged, missing or
leaking.
Notify the service.
Vacuum hose is loose, leaking
or clogged.
Notify the service.
Chamber lid gasket is not air-
tight.
Notify the service.
Vacuum sensor is defective. Notify the service.
Vacuum pump is not being
triggered or the vacuum pump
is defective.
Notify the service.
Vacuum pump is leaky. Notify the service.
Filter in the line to the vacuum
sensor is dirty and blocked.
Notify the service.
Leak in hose connections. Notify the service.
Leak in vacuum hose. Notify the service.
80
The vacuum sensor and as-
sociated line is leaking.
Notify the service.
81 Sealing diaphragm leaks. Notify the service.
8.2 Faults without diagnostic message
Symptom Cause Solution
Machine is switched off. Switch on the machine.
Mains plug is unplugged. Plug in the mains plug.
Machine does not run.
Ambient temperature too low. Operate the machine only at
permissible ambient tempera-
ture, see "Technical Specifica-
tions".
Chamber lid pressed closed
too briefly.
Press the chamber lid shut
more evenly, more firmly and
for longer.
Chamber lid gasket is dirty. Clean the chamber lid gasket.
Chamber lid does not
remain closed despite
pump running.
Chamber lid gasket is dam-
aged.
Change chamber lid gasket.
Poor vacuum in the
pack.
Evacuation pressure is set too
high.
• Reduce Evacuation pressure
value.