Troubleshooting
Faults without diagnostic message
76 03.06.2014
Symptom Cause Solution
Gas flushing pressure is set
too high.
• Reduce Gas flushing pressure
value.
Gas flushing time is set too
high.
• Reduce Gas flushing time
value.
Pouch neck is clamped by
chamber lid.
Insert the film pouch so that
the pouch neck lies within the
chamber. Cut off the pouch
neck if necessary.
Chamber lid gasket is dirty. Clean the chamber lid gasket.
Insufficient oil quantity or oil in
the vacuum pump is too old.
Refill or replace oil.
Chamber lid gasket is dam-
aged.
Change chamber lid gasket.
Moist or liquid products give
off steam during the evacua-
tion process.
Abort the evacuation process
with the <Stop> key in case
the chamber lid mists up.
Pack product with the Auto-
matic function. Set the value
for the Automatic sensitivity.
Evacuation system is leaking. Notify the service.
Sealing time is set incorrectly. Increase the value for Sealing
time in small increments.
Pouch neck is clamped by
chamber lid.
Insert the film pouch so that
the pouch neck lies within the
chamber. Cut off the pouch
neck if necessary.
Seal seam is dirty. Keep the inside of the film
pouch in the area of the seal
seam clean.
Film pouch damaged. Use a new film pouch.
Film pouch not suitable. Use a film pouch suitable for
sealing.
Pouch neck is clamped by
chamber lid.
Insert the film pouch so that
the pouch neck lies within the
chamber.
Pack is leaking.
Film pouch not suitable. Use a film pouch suitable for
sealing.