Maintenance
Change the air de-oiling element
68 03.06.2014
WARNING
Burn hazard!
The surface of the vacuum pump can reach temperatures of over
70 °C during operation.
Touching the vacuum pump can lead to burns.
Before performing any work on the vacuum pump:
¾ Allow the vacuum pump to cool down.
¾ Wear personal protective equipment.
¾ Remove the safety guard on the back of the machine.
¾ Open the chamber lid.
¾ Take all the objects out of the chamber apart from the sealing bar.
¾ Unscrew the screws.
¾ Carefully fold open the bottom section and insert the retaining rod
in the holding device.