Description
Display
03.06.2014 25
Numeric display
• During the packaging procedure: display of
the remaining time of the current process.
• With chamber lid opened: display of the
times currently set.
Icon for pump protec-
tion
• Icon is not displayed: pump protection
function is inactive.
• Icon flashes: pump protection function is
running.
• Symbol is displayed continuously: pump
protection function is activated and can be
started by pressing the chamber lid shut.
Recipe display Shows the currently loaded recipe. If the cur-
rent settings have not yet been saved as a
recipe, no number is displayed.
Display of the unit
• Unit 's' is displayed: the time in the display
is shown in seconds.
• There is no unit displayed: the time in the
display is shown in minutes.
Function display The function display shows the active proc-
esses for the packaging procedure and the
progress within the packaging procedure. The
individual processes are depicted as symbols.
Meaning when the chamber lid is open:
• Symbol is not displayed: the process is
bypassed during the packaging procedure.
• Icon flashes: the time which is called up
can be set with the arrow keys.
• Symbol is displayed continuously: the
process is performed during the packaging
procedure.
Meaning during the packaging procedure:
• Icon is not displayed: the process has
been performed or bypassed.
• Icon flashes: the process is just being per-
formed.
• Icon is continuously displayed: the process
has not yet been performed.
2.5 Process sequence
The film pouches are filled and laid in the chamber. When the cham-
ber is closed, the following processes run automatically: