Operation
Working with recipes
03.06.2014 47
Info
If the settings are changed after a recipe has been loaded, the rec-
ipe number goes out in the display.
4.8.2 Save recipe
¾ Hold the desired key <1> to <3> pressed down for 5 s.
The recipe number flashes in the display and is then displayed
continuously.
A recipe which is already saved is overwritten.
The current values are stored in the selected recipe.
4.9 Perform pump protection function
¾ Press the <Pump protection> key.
The "pump protection" icons appears in the display.
The duration of the pump protection function is displayed in
minutes.
The pump protection function is activated.
¾ To deactivate the pump protection function, press the <Stop> key
again.
The "pump protection" icon goes out.
The pump protection function is deactivated.
¾ To start the machine after it has been switched on, firmly press
the opened chamber lid shut against the resistance by pressing
the middle of its front edge.
The pump protection function starts.
The "pump protection" icon flashes.
The vacuum pump runs for 20 minutes.
The chamber lid opens automatically.
The display goes dark.
¾ To abort the pump protection function, press the <Machine control
On/Off> key, while the vacuum pump is running.
The chamber lid opens automatically.
The display goes dark.