Maintenance
Service recommendation
60 03.06.2014
¾ Check the chamber lid for damage (e.g scratches, cracks), defor-
mation and misting.
¾ If the chamber lid is damaged, deformed or misted up, have it
replaced by the service department.
¾ Check chamber lid gasket for damage.
¾ If necessary, replace the chamber lid gasket, see Section 7.8
"CHANGE CHAMBER LID GASKET".
¾ Check sealing bar for damage.
¾ If necessary, replace the sealing bar, see Section 7.3 "RE-
PLACE THE SEALING BAR".
¾ Check the counter-pressure bar for damage.
¾ If necessary, repair the counter-pressure bar, see Section 7.4
"REPAIR COUNTER-PRESSURE BAR".
7.2.3 Entire machine - Alkaline cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.4 Entire machine - Perform a wipe test
¾ Check the result of the cleaning and disinfection by means of a
wipe test.
See the company cleaning guidelines and recommendations see
Section 6 "CLEANING".
7.2.5 Entire machine - Acidic cleaning and disinfection
¾ See company cleaning guidelines and see Section 6 "CLEANING".
7.2.6 Connections - Visual inspection
¾ Disconnect the machine from the mains electricity.
¾ Check power cable for damage.
¾ If present, check that the supply line for inert gas is fitted tightly
and undamaged.
7.2.7 Vacuum pump - Checking oil level, topping up
¾ Check the oil level on the oil sight glass.
¾ If water is present in the oil, change the oil in the vacuum
pump, see Section 7.6 "CHANGE THE OIL IN THE VACUUM PUMP".