Cleaning
Notes on cleaning
52 03.06.2014
6.1.5 Instructions on the handling of anti-corrosion
agents and lubricants
Excess lubricants can accumulate at lubrication points. Excess
grease has no lubricating function; however, it can breed micro-
organisms and contaminate the product.
For type of anti-corrosion agent, refer to "Care products table".
Always follow the instructions for use from the manufacturer of the
anti-corrosion agent or lubricant.
Check the lubricating points regularly for the accumulation of lubri-
cants and remove excess lubricant.
Only use H1 or FDA-approved lubricants and anti-corrosion agents.
Regular checking of the microbiological shelf life of the anti-
corrosion agent and lubricant helps to reduce the risk of product
contamination.
6.1.6 Instructions on the handling of cleaning devices
The cleaning devices will become germ hot spots if they are not
cleaned often enough. This can cause cross contamination, which
will damage the product. Use only plastic brushes and brooms.
Clean the cleaning devices daily and apply disinfectant afterwards.
The exhaust air emitted and agitated by the vacuum cleaner must
comply with the prescribed limit values for the packaging environ-
ment. Accordingly, the appropriate filter elements must be used in
the vacuum cleaner.
6.2 Cleaning recommendations
Info
Always clean the machine from top to bottom.
In the following, optional equipment versions are also described.
Only perform steps that correspond to the version of the ma-
chine.
The illustrations are examples.
¾ Open the chamber lid. Open the chamber lid more than half way
so that it remains open.
The chamber lid remains open in the middle position.
¾ Remove all products from the chamber.
¾ Switch off the machine.
¾ Disconnect the machine from the mains electricity.
¾ Cover the mains plug with waterproof plastic bags.
¾ Close the stop-cock for the gas supply, if part of the machine.