4.2.2 Environmental characteristics
Climatic
Operating temperature -25 °C ... +55 °C
Storage temperature -25 °C ... +70 °C
provide acclimatization
for commissioning
Transport temperature -25 °C ... +70 °C
provide acclimatization
for commissioning
Relative humidity ≤95 %
Installation height Above sea level ≤2000 m
Mechanical
Vibration test EN 60068 Parts 2-6 10 ... 58 Hz,
amplitude
0.35 mm,
58 ... 150 Hz; 20 g
Shock test EN 60068 Parts 2-27 50 g, duration 11 ms
Electrical safety
Degree of protection EN 60529 IP67
Protection class When using an SELV or PELV power supply III
Degree of pollution 2
Emitted EMC interference
Radio interference field strength of hous-
ing
EN 55016-2-3 Compliant
Interference voltage EN 55016-1-2 Compliant
EMC immunity
Electrostatic discharge (ESD) EN 61000-4-2 Compliant
High-frequency electrical fields EN 61000-4-3 Compliant
Fast transient burst EN 61000-4-4 Compliant
Voltage surges EN 61000-4-5 Compliant
Conducted HF EN 61000-4-6 Compliant
Magnetic field 50/60 Hz EN 61000-4-8 Compliant
Voltage dips EN 61000-4-11 Compliant