Touch Screen Calibration 4-71
Calibration Procedures
Note: In order to achieve an accurate calibration the touch display must in the normal
operating position when AC power is applied to the terminal (45 degrees can be
assumed if this not known). If this was NOT done properly then begin with Step 1.
Otherwise skip to Step 2.
1. Select StartProgramsMicrochip TSHARC Control Panel.
Note: The Calibration program can also be started with the Touch icon at the
bottom of the screen.
2. Select the Calibration Tab.
3. Select 9-Point w/Linearization.
4. Select the Begin Linearization button.