NCR RealScan 7875-7000/8000 Installation Guide 
AIP-00342    Release B  06/03 
25 of 56
Over-Capacity Test 
This test checks for the proper indication from the scale when too much weight is placed on the 
top plate.  
Note: This test must immediately follow the increasing load test; do not remove any of the 
weights prior to running this test. 
Place additional weight on the top plate as shown in the following chart. Use the weight that 
corresponds to the RealScan 7875 weight feature. The display shows a series of dashes to 
indicate an over-capacity condition. 
 
Step  Weight Feature  Add Weight  Remove Weight  Display Result 
1  9.995 kg  0.04 kg    --.--- 
  13.995 kg  0.04 kg    --.--- 
 
30.0 lb.  0.08 lb.    --.--- 
2 
9.995 kg    0.04 kg  9.995 ± 0.005 kg 
  13.995 kg    0.04 kg  13.995 ± 0.005 kg 
 
30.0 lb.    0.08 lb.  30.0 ± 0.01 lb. 
 
Note: Remove only the "over capacity" weights before proceeding. 
Decreasing Load Test 
This test checks the scale’s accuracy when incrementally removing weight from the top plate. 
Use weights that correspond to the RealScan 7875 weight feature. 
Note: This test must immediately follow the over-capacity test; do not remove any of the 
weights prior to running this test. 
 
Step  Weight Feature  Add Weight  Remove Weight  Display Result 
1  9.995 kg    2.495 kg  7.5 ± 0.005 kg 
  13.995 kg    3.995 kg  10.0 ± 0.005 kg 
 
30.0 lb.    10.0 lb.  20.0 ± 0.01 lb. 
2 
9.995 kg    5.0 kg  2.5 ± 0.00 kg 
  13.995 kg    7.5 kg  2.5 ± 0.00 kg 
 
30.0 lb.    15.0 lb.  5.0 ± 0.00 lb. 
3 
9.995 kg  0.1 kg  2.5 kg  0.1 ± 0.00 kg 
  13.995 kg  0.1 kg  2.5 kg  0.1 ± 0.00 kg 
 
30.0 lb.  0.2 lb.  5.0 lb.  0.2 ± 0.00 lb. 
4 
9.995 kg    0.1 kg  0.0 ± 0.00 kg 
  13.995 kg    0.1 kg  0.0 ± 0.00 kg 
 
30.0 lb.    0.2 lb.  0.0 ± 0.00 lb.