Power Failure Telephone
56 Optional Equipment DSX-40 Hardware Manual
Power Failure Telephone
Power Failure Cut-Through
When AC power fails, the system can automatically cut through to a Power Failure Telephone connection.
Analog stations 25 and 26 (extensions 324 and 325) are the permanent power failure extensions. When
power fails:
Analog extension 324 (station 25) automatically cuts through to line 1.
Analog extension 325 (station 26) automatically cuts through to line 2.
For more on connecting extensions, see Connecting Extensions and Lines (page 28).
To test the Power Failure Telephone:
1. Connect the power failure telephone.
2. Power down the system.
3. At the Power Failure Telephone, lift the handset.
- You should hear dial tone on the line you connected.
- Place a test call.