SSA Scripting 93
The specified RAID level is invalid or is not possible
with the current physical disk and array
configuration.
The specified size is invalid or is not possible with
the current configuration.
The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the
current configuration.
Invalid ClearConfigurationWithDataLoss
parameter
The valid parameters are Yes and No (default).
Controller does not support Chassis Name
The controller does not support setting a chassis
name.
The entered chassis name is invalid. Use characters
from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _,
+, :, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
The requested SSP state is not a valid SSP state.
Cannot change SSP settings
The SSP settings cannot be changed for the
controller or logical drive.
The adapter ID is not a valid adapter ID that was
detected by the controller.
Invalid Surface Scan Delay
Controller does not support redundancy
settings
The controller is not redundant or does not support
redundancy settings.
Invalid Preferred Path Mode
The specified value for the preferred path mode is
not valid, or the controller is not available.
The specified preferred path is not a valid chassis
slot for an available, active controller, or the
controller is not available.
Failure opening capture file
Failure opening input file
Failure opening error file
There are no suitable spares available
SSA found no drives that could be used as spares for
the specified array.
Invalid Physical Disk Type Specified
The specified value for MNP delay is invalid.
Invalid Cache Logical Drive
The specified caching logical drive ID is invalid.
The specified caching array ID is invalid.
Error creating Caching Logical Drive
Error creating Caching Array
Error modifying Caching Volume
Unable to modify Caching Arrays
Caching arrays cannot be modified once created.
The requested Array modification is invalid
Error specifying the list of drives when reconfiguring
an array