Issue 5.0 UNIVERGE SV8100
1 - 92 Automatic Release
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
14-02-09 Analog Trunk Data Setup – Busy
Tone Detection
This option enables/disables Busy
Tone Detection.
0 = Disable (No)
1 = Enable (Yes)
(default = 0)
14-02-14 Analog Trunk Data Setup – Loop
Start/Ground Start
This option identifies the analog
trunk as either loop or ground
start.
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
(default = 0)
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use this option to set the
Detection Level.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0