Issue 5.0 UNIVERGE SV8100
1 - 102 Automatic Route Selection
12-04-01 Holiday Night Service Switching Define a yearly schedule of
holiday night-switch settings. This
schedule is used for setting
special days when the company is
expected to be closed, such as
national holidays.
Days and Months:
0101~1231
(e.g. 0101 = Jan. 1;
1231 = Dec. 31)
Time Pattern Number:
0~10
(0 = No Setting)
(default not assigned)
12-05-01 Night Mode Group Assignment
for Extensions
Assign Day/Night Mode Group for
each extension.
Night Mode Service
Group Number:
01~32
(default = 1)
12-06-01 Night Mode Group Assignment
for Trunks
Assign a Day/Night Mode Group
for each trunk port.
Trunk Port Number:
001~200
Night Mode Service
Group Number:
01~32
(default Night Mode
Service Group
Number = 1)
12-07-01 Text Data for Night Mode Use this program to make an
original text message, which,
depending on programming, can
be displayed on an LCD of a
multiline telephone in each Mode.
Night Mode Service
Group Number:
01~32
Day/Night Mode: 1~8
Text Message:
Maximum 12
Characters (alphabetic
or numeric)
Default Text Messages
for Day/Night Modes:
Mode 1 = No Setting
Mode 2 = <Night>
Mode 3 = <Midnight>
Mode 4 = <Rest>
Mode 5 = <Day2>
Mode 6 = <Night2>
Mode 7 = <Midnight2>
Mode 8 = <Rest2>
12-08-01 Night Mode Service Range Define the changing range of
toggle key for each Day/Night
Mode.
Night Mode Service
Group Number:
01~32
Range: 2~8
(default = 2)
Program