Issue 5.0 UNIVERGE SV8100
1 - 1114 Voice Over
Related Features
Conference
Off-Hook Signaling
Programmable Function Keys
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
11-12-41 Service Code Setup (for System
Access) – Voice Over
The service code used for the
Voice Over feature (default: 890).
. To use Service Code 890 for
Voice Over, Program
11-16-08 (Single Digit
Service Code Setup – Voice
Over) must be undefined.
MLT
(default = 890)
11-16-08 Single Digit Service Code Setup
– Voice Over
Service code used for the Voice
Over feature (default: not
assigned).
(default not assigned)
15-07-01 Programmable Function Keys Assign a function key for Voice
Over (code 48).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
Allows a busy extension to
manually (0) or automatically (1)
receive off-hook signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)