Issue 5.0 UNIVERGE SV8100
1 - 1132 Voice Response System (VRS)
25-07-02 System Timers for VRS/DISA –
VRS/DISA No Answer Time
If an Automated Attendant caller
dials an extension that does not
answer, the call waits this interval
before rerouting to the Ring Group
specified in PRG 25-03 and PRG
25-04. This setting also affects
unanswered DISA calls.
0~64800 (seconds)
(default = 0 seconds)
25-07-03 System Timers for VRS/DISA –
Disconnect after VRS/DISA
retransfer to IRG
Set the timer for disconnecting a
call after it is re-transferred to a
ring group by VRS/DISA.
0~64800 (seconds)
(default = 60 seconds)
25-08-01 DISA User ID Setup – Password Set up password (six digits). Dial (Six digits fixed)
(0~9,
*, #)
(default not assigned)
25-13-01 System Option for DISA – VRS
Message Access Password
Enter the password DISA callers
must dial before the system allows
them to record, listen to or erase
VRS messages.
1~ 9, 0, *, #
Six digits fixed
(default not assigned)
25-15-01 DISA Transfer Target Setup –
DISA Transfer Target Area at
Wrong Dial
Used to assign a speed dial
number when the wrong number is
received.
Speed Dial bin number
0 ~ 1999
(default = 1999)
Version 3 software or
higher is required
25-15-02 DISA Transfer Target Setup –
DISA Transfer Target Area at No
Answer or Busy
Used to assign a speed dial
number when a dial tone times-out
and the target extension does not
answer or is busy.
Speed Dial bin number
0 ~ 1999.
(default = 1999)
Version 3 software or
higher is required.
31-02-01 Internal Paging Group
Assignment – Internal Paging
Group Number
Assign extensions to Internal
Paging Groups (i.e., Page Zones).
0~64
(0 = No Setting)
Default:
0 for IP Station
1 for TDM Station
31-02-02 Internal Paging Group
Assignment – Internal All Call
Paging Receiving
Enable or disable All Call Internal
Paging for each extension. If
allowed, extension can place and
receive All Call Internal Paging
announcements. If prevented,
extensions can only make (not
receive) All Call Internal Paging
announcements. If combined,
Paging zones should be restricted
as well, change the internal page
zone group in Program 31-07-01
to 0.
0 = Off
1 = On
(default = 0)
Program
Number
Program Name Description/Comments Assigned Data