UNIVERGE SV8100 Issue 5.0
Voice Response System (VRS) 1 - 1131
25-04-01 VRS/DISA Transfer Ring Group
With No Answer/Busy
Set the destination that Automated
Attendant (OPA) calls ring if the
OPA caller dials an extension that
does not answer or is busy. This
also sets the options for DISA
calls. The system allows Ring
Groups or Disconnect = 0.
Ring Groups:
1~100
Trunk Ports:
001~200
Day/Night Mode:
1~8
0 (Disconnect)
1~100 (Incoming Ring
Group)
102 (In-Skin/External
Voice Mail or InMail)
(default = 0)
104 (Speed Dial table
Program 25-15-02)
Version 3 software or
higher is required.
(default = 0)
25-05-01 VRS/DISA Error Message
Assignment
For each trunk that is answered by
the VRS, enter the VRS message
(1~100) the outside caller hears if
they dial incorrectly after answer. If
you enter 0, the call reroutes
according to Program 25-03 and
Program 25-04. Make one entry
for each Night Service mode.
0~100 (0 = No Setting)
(default = 0)
25-06-01 VRS/DISA One-Digit Code
Attendant Setup – Next
Attendant Message Number
Set up single digit dialing for
Automated Attendant callers. For
each VRS Message programmed
to answer outside calls (see
Program 25-02-01), specify the
digit the Automated Attendant
caller dials (1~9, 0,
*, #). (Keep in
mind that if you assign
destinations to digits 3 and 4,
outside callers cannot dial system
extensions.)
0~100 (0 = No Setting)
101 = Voice MAil
Answers
104 = Refer to 25-04:
VRS/DISA Transfer
Ring Group with No
Answer/ Busy
105 = Dial the other
extension
(default = 0)
25-06-02 VRS/DISA One-Digit Code
Attendant Setup – Destination
Number
Set up single digit dialing for
Automated Attendant callers. For
each VRS Message programmed
to answer outside calls (see
Program 25-02-01), specify the
destination reached (four digits
maximum) when the caller dials
the single digit code.
Up to eight digits
(default not assigned)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents