UNIVERGE SV8100 Issue 5.0
Barge-In 1 - 123
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
11-12-08 Service Code Setup (for Service
Access) – Barge-In
Determine what the service code
should be for an internal party to
use the Barge-In feature.
MLT, SLT
(default = 810)
11-16-02 One-Digit Service Code Setup –
Barge-In
Use this option to set up Item 02
for single digit Barge-In. For
example, you can assign Item 02
to use digit 5 for Barge-In. This
allows you to program a function
key with an extension number plus
the Barge-In code (i.e., 5). This
allows one-touch access to the
Barge-In feature for extension.
(default not assigned)
15-07-01 Programmable Function Keys Assign a function key for Barge-In
(code 34).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
Enables the extension Barge-In
Mode to be speech mode (0) or
Monitor mode (1).
0 = Off
1 = On
(default: 0 for COS
1~15)
20-13-15 Class of Service Options
(Supplementary Service) –
Barge-In, Initiate
Turns Off (0) or On (1) an
extension user ability to barge-in
on other's calls.
0 = Off
1 = On
(default: 0 for COS
1~15)
20-13-16 Class of Service Options
(Supplementary Service) –
Barge-In, Receive
In an extension Class of Service,
turn On (1) or Off (0) Barge-In at
the receiving extension (i.e.,
Barge-In receive).
0 = Off
1 = On
(default: 0 for COS
1~15)
20-13-17 Class of Service Options
(Supplementary Service) –
Barge-In Tone/Display (Intrusion
Tone)
In an extension Class of Service,
turn On (1) or Off (0) the Barge-In
(Intrusion) Tone. If disabled, this
also turns off the Barge-In display
at the called extension.
0 = Off
1 = On
(default: 1 for COS
1~15)