EasyManua.ls Logo

NEC Univerge SV8100 - Page 143

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 5.0
Call Appearance (CAP) Keys 1 - 133
Off-Hook Signaling
Programmable Function Keys
User Programming Ability
Virtual Extensions
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
15-07-01 Programmable Function Keys Use to assign functions to multiline
terminal line keys.
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
(
*08 + XXXX = CAP
key where XXXX is the
CAP orbit number
0001-9999)
20-02-23 Phone Operation Mode Selects the Loop Key operation
mode.
0 = Original Operation
Mode (CAP Key)
1 = Special Operation
Mode (Loop
Key)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
20-11-19 Class of Service Options (Hold/
Transfer Service) – Hold/
Extended Park
Determine whether an extension
Class of Service should allow
normal or extended Park
(0 = Normal for Program 24-01-06,
1 = Extended for Program
24-01-07).
0 = Off
1 = On
(default = 0 for COS
1~15)
24-01-01 Hold Recall Time A call on Hold recalls the
extension that placed it on Hold
after this time. This time works
with the Hold Recall Callback
Time.
0~64800 (seconds)
(default = 90)