Issue 5.0 UNIVERGE SV8100
1 - 134 Call Appearance (CAP) Keys
24-01-02 System Options for Hold – Hold
Recall Callback Time
A call that is parked longer than
the programmed interval recalls
the extension where it was initially
parked.
0~64800 (seconds)
(default = 30)
24-01-03 Exclusive Hold Recall Time A call left on Exclusive Hold recalls
the extension that placed it on
Hold after this time.
0~64800 (seconds)
(default = 90)
24-01-04 Exclusive Hold Recall Callback
Time
An Exclusive Hold Recall rings an
extension for this time. If not
picked up, the call goes back on
System Hold.
0~64800 (seconds)
(default = 30)
24-01-05 Forced Release of Held Call Depending on the setting of
Program 14-01-16, the system
disconnects calls on Hold longer
than this time.
0~64800 (seconds)
(default = 1800)
24-01-06 System Options for Hold – Park
Hold Time - Normal
Set the Park Hold Time (0~64800
seconds). A call that is parked
longer than the programmed time
recalls the extension where it was
initially parked.
Refer to Flexible System
Numbering on page 1-501 for
setting Flexible Timeouts for Class
of Service.
0~64800 (seconds)
(default = 90 seconds)
24-01-07 System Options for Hold – Park
Hold Time - Extended (Recall)
Set the Extended Park Hold Time
(0~64800 seconds). A call that is
parked longer than the
programmed time recalls the
extension where it was initially
parked.
0~64800 (seconds)
(default = 300
seconds)
Program
Number
Program Name Description/Comments Assigned Data