Issue 5.0 UNIVERGE SV8100
1 - 168 Call Forwarding, Off-Premise
20-09-01 Class of Service Options
(Incoming Call Service) –
Second Call for DID/DISA/DIL/
E&M Override
Turns Off (0) or On (1) the
extension ability to receive a
second call from a DID, DISA, DIL,
or tie line caller.
. With this option set to 1, the
destination extension must
be busy for a second DNIS
caller to ring through. If the
destination extension does
not have a trunk or CAP key
available for the second call
and a previous call is ringing
the extension but has not yet
been answered, the second
caller hears busy regardless
of this program setting.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-09-07 Class of Service Options
(Incoming Call Service) – Call
Queuing
Turn Off (0) or On (1) an extension
ability to have calls queued if a call
rings the extension when it is busy.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-11-12 Class of Service Options (Hold/
Transfer Service) – Call
Forwarding Off-Premise
(External Call Forwarding)
In an extensions Class of Service,
turn On (1) or Off (0) setting up
Call Forwarding Off-Premise at the
extension.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-05 Class of Service Options
(Supplementary Service) –
Intercom Off-Hook Signaling
Turn On (1) or Off (0) the ability of
an extension to receive Off-Hook
Signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
Allows a busy extension ability to
manually (0) or automatically (1)
receive Off-Hook signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
24-02-07 System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
Timer starts when a trunk begins
talking with another trunk (for
example: Trunk-to-Trunk Transfer,
outgoing from trunk, Tandem
Trunking). When this time expires,
a warning tone is heard.
0~64800 (seconds)
(default = 1800
seconds)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents