Issue 5.0 UNIVERGE SV8100
1 - 290 Code Restriction
21-06-02 Toll Restriction Table Data Setup
– International Call Permit Code
Table
Enter the international dialing
codes you want to permit.
Dial (Up to six digits)
Default:
Tables 1~20 = No
Setting
21-06-03 Toll Restriction Table Data Setup
– Maximum Number of Digits
Table Assignment
Select the maximum number of
digits allowed in outgoing calls for
each table (4~30).
4-30
default:
Tables 1~ 4 = 30
21-06-04 Toll Restriction Table Data Setup
– Common Permit Code Table
Program codes into the Common
Permit Code Table.
Dial (Up to four digits)
default:
Table 1 ~ 10 = No
Setting
21-06-05 Toll Restriction Table Data Setup
– Common Restriction Table
Program codes into the Common
Restrict Code Table.
Dial (Up to 12 digits)
default:
Tables 1~ 10 = No
Setting
21-06-06 Toll Restriction Table Data Setup
– Permit Code Table
Program codes into the Permit
Code Tables.
Dial (Up to 12 digits)
default:
Table 1~4 = No Setting
21-06-07 Toll Restriction Table Data Setup
– Deny Restriction Table
Program codes into the Restrict
Code Tables (200 codes per table
maximum).
Dial (Up to 12 digits)
default:
Table 1~4 = No Setting
21-06-08 Toll Restriction Table Data Setup
– PBX Access Code
The system allows up to four
tables for PBX access codes.
PBX Access Codes can have up
to two digits, using 0~9,
#, * and
LINE KEY 1 (don’t care). Refer to
the PBX Compatibility feature for
the specifics.
Dial (Up to two digits)
default:
Table 1~4 = No Setting
21-21-01 Toll Restriction for Trunks
(Seized Trunk Basis Setting) –
Restriction Class
Enter the Toll Restriction Class for
the selected trunk.
1~15
(default = 1)
34-01-05 E&M Tie Line Basic Setup –
System Toll Restriction
Determine if an incoming Tie Line
call should be subject to Toll
Restriction.
0 = No (Off)
1 = Yes (On)
(default = 0)
34-08-01 Toll Restriction Data for E&M Tie
Lines
Define the Toll Restriction data for
E&M Tie Lines. This data should
be defined if Tie Line Code
Restriction is enabled in Program
21-05-13.
Up to 10 digits
(0~9,
*, #)
(default not assigned)
Program