UNIVERGE SV8100 Issue 5.0
Department Calling 1 - 349
11-11-29 Service Code Setup (for Setup/
Entry Operation) – Delayed
Transfer Cancellation for Each
Extension Group
Use this service code to cancel the
delayed transfer destination
Department Group.
MLT, SLT
(default = 706)
11-12-09 Service Code Setup (for Service
Access) – Change to STG
(Department Group) All Ring
Use this option to set the service
code for ringing all members of a
Department Group.
MLT, SLT
(default = 780)
11-16-10 Single Digit Service Code Setup
– (Department) STG All Ring
Mode
Assign the Single Digit
(post-dialing) Service Code for All
Member Ring.
(default not assigned)
15-07-01
Programmable Function Keys
Assign a Department Calling key
(46) so extension users can install
or remove themselves from the
Department Calling Group.
Additional keys can also be
assigned for Department Group
features immediate calling
destination (58), delayed calling
destination (59) and DND
destination (60).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
16-01-01 Department Group Basic Data
Setup – Department Name
Assign a name to the Extension
(Department) Groups.
Maximum 12
characters
(default not assigned)
16-01-02 Department Group Basic Data
Setup – Department Calling
Cycle
Set the routing cycle for calls into
a department (i.e., when a user
dials the department pilot
number). The system can ring the
highest priority extension available
(Priority Routing, 0) or cycle in
circular order to a new idle
extension for each new call
(Circular Routing, 1).
0 = Normal Routing
(Priority)
1 = Easy – UCD
Routing (Circular)
(default = 0)
16-01-03 Department Group Basic Data
Setup – Department Routing
When Busy (Auto Step Call)
Set how the system routes an
Intercom call to a busy
Department Group member. The
caller can hear busy tone (0) or
overflow to the first available
Department Group member (1).
This option is for Intercom calls to
an extension, not a pilot number.
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle member)
(default = 0)
16-01-04 Department Group Basic Data
Setup – Hunting Mode
Set if an unanswered call should
hunt once stopping at the last
member tried (0) or continually
hunt through the idle members (1).
0 = Last extension is
called and hunting is
stopped
1 = Circular
(default = 0)