UNIVERGE SV8100 Issue 5.0
Door Box 1 - 461
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
10-03-01
(1)
ETU Setup (DLCA PKG Setup) –
Terminal Type (B1)
Use to setup and confirm the
Basic Configuration data for
terminal type (B1).
0 = Not set
1 = Multiline Terminal
2 = SLT Adapter
3 = Bluetooth Cordless
Handset
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Doorbox)
9 = PGD (ACI)
10 = DSS Console
11 = -- Not Used --
(default = 0))
10-03-06 ETU Setup (DLCA PKG Setup) –
Terminal Type (B2)
Use to setup and confirm the
Basic Configuration data for
terminal type.
For DLC package support, set the
terminal type to 8 [PGD (for Door
Box)]. First set 10-03-01 to 0 with
no device plugged into that port,
then plug the device in and the
system should recognize it as a
door box and then set Program
10-03-06.
0 = Not set
6 = PGD(2)-U10 ADP
(Paging)
7 = PGD(2)-U10 ADP
(Tone Ringer)
8 = PGD(2)-U10 ADP
(Door Box)
9 = PGD(2)-U10 ADP
(ACI)
12 = APR (B2 Mode)
(default = 0)
10-05-01 General Purpose Relay Setup –
Slot No. Physical Port of DLCA
Sensor Circuit No.
Define which Relay circuits (5~8)
on a PGD(2)-U10 ADP Adapter
are used for General Purpose
Relay.
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
. After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
11-12-36 Service Code Access (for
Service Access) – Door Box
Access
If the service code for Doorphone
Access is not acceptable, change
it here.
MLT, SLT
(default = 802)
15-07-01 Programmable Function Keys Assign a function key for External
Call Forward by Doorphone (Code
54).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
32-01-01 Door Box Timers – Door Box
Answer Time
Set the time a user has to answer
the Door Box chimes.
0~64800 (seconds)
(default = 30 seconds)