EasyManua.ls Logo

NEC Univerge SV8100 - Page 472

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 5.0 UNIVERGE SV8100
1 - 462 Door Box
32-01-02 Door Box Timers – Door Lock
Cancel Time
Set the time the Door Box strike
stays open when the single line
telephone user hookflashes or a
multiline terminal user presses the
Recall key.
0~64800 (seconds)
(default = 10 seconds)
32-01-03 Door Box Timers – Off-Premise
Call Forward by Door Box
Disconnect Timer
Define the conversation period for
an Off-Premise Call Forward by
Door Box call. When this timer
expires, the caller hears busy tone
for 3 seconds (fixed time), and the
call is then disconnected.
0~64800 (seconds)
(default = 60 seconds)
32-02-01 Door Box Ring Assignments Determine which Door Boxes
should ring which extensions by
entering the extension number.
Each Door Box can be
programmed to ring up to 32
extensions and an extension can
be programmed to ring for multiple
Door Boxes.
Maximum eight digits
(default not assigned)
32-03-01 Door Box Basic Setup – Chime
Pattern
Set the chime pattern (0~6) for
each Door Box.
0 = None
1 = Door Box Ring 1
2 = Door Box Ring 2
3 = Door Box Ring 3
4 = Door Box Ring 4
5 = Door Box Ring 5
6 = Door Box Ring 6
default:
Door Box 1 = 1
Door Box 2 = 2
Door Box 3 = 3
Door Box 4 = 4
Door Box 5 = 5
Door Box 6 = 6
Door Box 7 = 1
Door Box 8 = 1
32-03-02 Door Box Basic Setup – CODEC
Transmit Gain Setup
Set the Transmit Gain for each
Door Box.
1~63 (-15.5dB ~
+15.5dB)
(default = 32)
32-03-03 Door Box Basic Setup – CODEC
Receive Gain Setup
Set the Receive Gain for each
Door Box.
1~63 (-15.5dB ~
+15.5dB)
(default = 32)
32-04-01 Doorphone Name Setup This command defines the name
of each Doorphone
Up to 12 characters
(default not assigned)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents