UNIVERGE SV8100 Issue 5.0
Drop Key 1 - 469
Operation
To use the Drop key from a Multiline Terminal with a CO/PBX call in progress:
1. Press the Function key programmed as a Drop key.
2. Receive the new CO/PBX dial tone.
3. Dial the desired number.
81-10-07 COI Initial Data Setup –
Hookflash Time Selection 1
Set the Flash duration (20 mS~5.0
sec) for analog trunk [COI( )-U( )
ETU] circuits.
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 9 (600ms)]
81-10-08 COI Initial Data Setup –
Hookflash Time Selection 2
Set the open loop disconnect
duration (20 mS~5.0 sec) for
analog trunk [COI( )-U( ) ETU]
circuits.
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 14 (3.0
seconds)]
Program
Number
Program Name Description/Comments Assigned Data