UNIVERGE SV8100 Issue 5.0
Flexible Timeouts 1 - 525
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
20-01-08 System Options – Trunk
Queuing Callback Time
Set the Trunk Queuing callback
time. A Trunk Queuing Callback
rings an extension for this interval.
0~64800 (seconds)
(default = 15 seconds)
20-01-09 System Options – Callback/
Trunk Queuing Cancel Time
The system cancels an extension
Callback or Trunk Queueing
request after this interval.
0~64800 (seconds)
(default = 64800
seconds)
20-04-03 System Options for Virtual
Extensions – Virtual Extension
Delay Interval
Virtual Extensions set for Delayed
Ringing (see Program 15-11) ring
the extension after this interval.
0~64800
(default = 10 seconds)
20-29-01 Timer Class for Extensions Assign the timer class (0~15) to
each extension for each Night
mode. This entry includes virtual
extension number.
0~15
0 = Not assigned
(default = 0)
20-30-01 Timer Class for Trunks Assign the timer class (0~15) to
each trunk for each Night mode.
0~15, #, *
0 = Not assigned
(default = 0)
20-31-01 Timer Class Timer Assignment –
Trunk Queuing Callback
Duration Time
Trunk Queuing Callback rings an
extension for this amount of time.
0~64800 (seconds)
(default = 15 seconds)
20-31-02 Timer Class Timer Assignment –
Callback / Trunk Queuing Cancel
Time
The system cancels an extension
Callback or Trunk Queueing
request after this amount of time.
0~64800 (seconds)
(default = 64800
seconds)
20-31-03 Timer Class Timer Assignment –
Virtual Extension Delay Interval
Virtual Extensions set for Delayed
Ringing (refer to 15-11: Virtual
Extension Delayed Ring
Assignment) ring the extension
after this interval.
0~64800 (seconds)
(default = 10 seconds)
20-31-04 Timer Class Timer Assignment –
Intercom Interdigits Time
(Intercom I/D Timer)
When placing Intercom calls,
extension users must dial each
digit in this time.
0~64800 (seconds)
(default = 10 seconds)
20-31-05 Timer Class Timer Assignment –
Trunk Interdigits Time (Trunk I/D
Timer)
The system waits for this time to
expire before placing the call in a
talk state (Call Timer starts after
time expires, Voice Over and
Barge-In are not allowed until after
time expires).
0~64800 (seconds)
(default = 5 seconds)
20-31-06 Timer Class Timer Assignment –
Hotline Time Start Time (Hotline
Start)
A Ringdown extension
automatically calls its programmed
destination after this time.
0~64800 (seconds)
(default = 5 seconds)