UNIVERGE SV8100 Issue 5.0
Hotel/Motel 1 - 587
11-14-15 Service Code Setup (for Hotel) –
Room Status Change for Other
Extension
Customize the room status
change for other extension
Service Codes which are used
with the Hotel/Motel feature
(CD-CP00 must be licensed for
Hotel/Motel).
MLT, SLT
(default = 741)
11-14-16 Service Code Setup (for Hotel) –
Room Status Output
Customize the room status output
Service Codes used with the
Hotel/Motel feature (CD-CP00
must be licensed for Hotel/Motel).
MLT
(default = 742)
11-14-17 Service Code Setup (for Hotel) –
Hotel Room Monitor
Customize the hotel room monitor
Service Codes used with the
Hotel/Motel feature (CD-CP00
must be licensed for Hotel/Motel).
MLT, SLT
(default = 770)
11-14-18 Service Code Setup (for Hotel) –
Set Hotel PMS Code Restriction
Customize the set hotel PMS code
restriction Service Codes used
with the Hotel/Motel feature
(CD-CP00 must be licensed for
Hotel/Motel).
MLT
(default = 766)
15-03-01 Single Line Telephone Basic
Data Setup – SLT Signaling Type
Determine the dialing type the
connected telephone uses.
0 = DP
1 = DTMF
(default = 1)
15-03-04 Single Line Telephone Basic
Data Setup – Flashing
Enable/Disable Flash for single
line (500/2500 type) telephones.
0 = No
1 = Yes
(default = 1)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension ports =
Class 1
20-13-11 Class of Service Options
(Supplementary Service) – Room
Monitor, Initiating Extension
Turn Off or On an extension user
ability to Room Monitor other
extensions.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turn Off or On an extension user
ability to use Continued Dialing,
which allows DTMF signal sending
while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-16 Class of Service Options
(Supplementary Service) –
Barge-In, Receive
Turn Off or On Barge-In at the
receiving extension (i.e., Barge-In
receive).
0 = Off
1 = On
(default = 0 for
COS 1~15)