UNIVERGE SV8100 Issue 5.0
Night Service 1 - 729
14-07-01 Trunk Access Map Setup To allow for Universal Night
Answer (UNA) answering, set up
the Trunk Access Maps (1~200).
For UNA, extension must have
incoming access to trunk ringing
the External Paging speakers.
0 = No access
1 = Outgoing access
only
2 = Incoming access
only
3 = Access only when
trunk on Hold
4 = Outgoing access
and access when trunk
on Hold
5 = Incoming access
and access when trunk
on Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk
on Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is
on Hold).
15-06-01 Trunk Access Map for
Extensions
For Universal Night Answer (UNA)
answering, assign Trunk Access
Maps (1~200) to extensions. Make
one entry for each Night Service
mode.
Trunk Access Maps:
1~200
(default = 1)
15-07-01 Programmable Function Keys Assign Night Service function keys
(09) to extensions and set the key
for the proper mode (Day, Night,
Rest, etc.). If the additional data is
set to 0, the toggle mode is
assigned.
For Line Keys: 1~48
0 ~ 99 (Normal
Function Code)
(default = Service
Code 851)
*00 ~ *99
(Appearance Function
Code) (default =
Service Code 852)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
Program
Number
Program Name Description/Comments Assigned Data