UNIVERGE SV8100 Issue 5.0
Off-Hook Signaling 1 - 737
20-13-34 Class of Service Options
(Supplementary Service) – Block
Manual Off-Hook Signaling
Turn Off (0) or On (1) an extension
ability to block off-hook signals
manually sent from a co-worker.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-18-06 Service Tone Timers – Interval of
Call Waiting Tone
Use this timer to set the time
between Off-Hook Signaling
alerts.
0~64800 (seconds)
(default = 10 seconds)
80-01-01
(39)
Service Tone Setup – Repeat
Count
Customize the system basic tones
and system service tones. You
need to reset for the changes to
take affect.
80-01-02
(39)
Service Tone Setup – Basic Tone
Number
The following features require that
the system tones listed below be
changed to match the table. After
changing these settings the
chassis must be reset for the
changes to take effect.