Issue 5.0 UNIVERGE SV8100
1 - 760 Paging, External
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
10-05-01 General Purpose Relay Setup –
Slot No. Physical Port of DLCA
Sensor Circuit No.
Define which relay circuits (5~8)
on the PGD(2)-U10 ADP are used
for General Purpose Relays.
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
10-21-04 CD-CP00 Hardware Setup –
External Source I/O Selection on
CD-CP00
Define what the I/O ports on the
CD-CP00 are used for.
0 = External MOH
(CN8)/ External
Speaker(CN9)
1 = BGM source
(CN8)/ External
Speaker(CN9)
2 = External MOH
(CN8)/BGM source
(CN9)
Relations
between CN
number and
Relay number are
as follows:
CN8 = Relay2
CN9 = Relay1
(default = 1)
11-12-50 Service Code Setup (For Service
Access) – General Purpose
Relay
Specify the service code to be
used for toggling the relay open
and closed.
MLT, SLT
(default = 880)
15-07-01 Programmable Function Keys Assign function keys for External
Paging zones (19 + zone) and
External All Call Page (20). If
required, define a function key for
a multiline terminal to use the
general purpose relay (51).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
20-13-29 Class of Service Options
(Supplementary Service) –
Paging Display
Turns Off (0) or On (1) an
extension user ability to display
paging information.
0 = Off
1 = On
(default = 1 for
COS 1~15)

Table of Contents