1 - 820 Q-Sig
44-05-09 F-Route Table – Maximum Digit Input the maximum number of
digits to send when using the
F-Route.
0~24
(default = 0)
44-05-11 F-Route – Network Specified
Parameter Table
For each F-Route table (1~500)
assign the priority (1~4). Assign
the Network Specified Parameter
Table (0~16).
0~16
(default = 0)
44-06-01 Additional Dial Table If an Additional Dial Number Table
is entered in Program 44-05-03,
define the additional dial table
(1~1000) to add digits in front of
the dialed F-Route number (24
digits max: 1-9, 0
* #, Pause). To
enter a wild card/don’t care digit,
press Line Key 1 to enter a P
(pause) symbol.
Up to 24 digits
Enter: 1~9, 0,
*, #,
Pause (press line key 1
to enter a pause)
(default not assigned)
44-07-01 Gain Table for F-Route Access –
Incoming Transmit
Set the gain table to be used
(1~500). If an extension dials F-
Route number;
The Extension Dial Gain Table is
activated, which is assigned in
Program 44-05.
The Extension Dial Gain Table
follows Outgoing transmit and
Outgoing receive settings.
If the incoming call is transferred
to another line using F-Route;
The Tandem Gain Table is
activated, which is assigned in
Program 44-05.
The Tandem Gain Table follows
the Incoming transmit and
Incoming receive settings for
incoming line, and Outgoing
transmit and Outgoing receive
settings for the outgoing line.
For F-Route calls, the CODEC
gains defined in Program 14-01-02
and Program 14-01-03 are not
activated.
1~63
(-15.5 ~ +15.5dB)
(default = 32)
44-07-02 Gain Table for F-Route Access –
Incoming Receive
1~63
(-15.5 ~ +15.5dB)
(default = 32)
44-07-03 Gain Table for F-Route Access –
Outgoing Transmit
1~63
(-15.5 ~ +15.5dB)
(default = 32)
44-07-04 Gain Table for F-Route Access –
Outgoing Receive
1~63
(-15.5 ~ +15.5dB)
(default = 32)
44-08-01 Time Schedule for F-Route Define the daily pattern of the F-
Route feature. F-Route has 10
time patterns. These patterns are
used in Program 44-09 and
Program 44-10. The daily pattern
consists of 20 time settings.
Time Number: 01~20
Start Time =
0000~2359
End Time = 0000~2359
Mode: 1~8
Default = All Schedule
Patterns: 0:00 – 0:00,
Mode 1
Program
Number
Program Name Description/Comments Assigned Data