UNIVERGE SV8100 Issue 5.0
Single Line Telephones 1 - 881
20-15-03 Ring Cycle Setup – Incoming
Internal Call
Define the ringing cycle (1~13) for
ICM calls.
Ringing Cycle = 1~13
(default = 12)
20-15-05 Ring Cycle Setup – DID/DDI Define the ringing cycle (1~13) for
DID calls.
Ringing Cycle = 1~13
(default = 8)
80-03-01 DTMF Tone Receiver Setup –
Detect Level
Use Items 11~32 to set the criteria
for dial tone detection for outgoing
ARS calls.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1~5 = 0
80-03-02 DTMF Tone Receiver Setup –
Start delay time
Use this option to define the start
delay time for DTMF Tone
Receiver.
0~255
(0.25 ms ~ 64 ms)
default:
Type 1~5 = 0
Program
Number
Program Name Description/Comments Assigned Data