EasyManua.ls Logo

NEC Univerge SV8100 - Page 927

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 5.0
Speed Dial – System/Group/Station 1 - 917
80-03-05 DTMF Tone Receiver Setup –
Forward twist level
Use to define the forward twist
levels for the DTMF Tone
Receiver.
0~9 (1dB ~ 10dB)
[default: Type 1~5 =
5 (6dBm)]
80-03-06 DTMF Tone Receiver Setup –
Backward twist level
Use to define the backward twist
levels for the DTMF Tone
Receiver.
0~9 (1dB ~ 10dB)
[default: Type 1~5 =
0 (1dBm)]
80-03-07 DTMF Tone Receiver Setup – ON
detect time
Use to define the on detect times
for the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
[default: Type 1~5 =
1 (30ms)]
80-03-08 DTMF Tone Receiver Setup –
OFF detect time
Use to define the off detect timer
for the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
[default: Type 1~5 =
1 (30ms)]
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use to define the detection levels
for the Call Progress Tone
Detector.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
80-04-02 Call Progress Tone Detector
Setup – Min. Detection Level
Use to define the minimum
detection levels for the Call
Progress Tone Detector.
0~15
detect level 0 : –15dBm
(0) to –30dBm(15)
detect level 1 : –30dBm
(0) to –45dBm(15)
detect level 2 : –40dBm
(0) to –55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
Program
Number
Program Name Description/Comments Assigned Data