Issue 5.0 UNIVERGE SV8100
1 - 974 Tandem Trunking (Unsupervised Conference)
Method B – Tandem Trunking with Transfer Key
Program
Number
Program Name Description/Comments Assigned Data
14-01-04 Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
14-01-05 Basic Trunk Data Setup –
Receive Gain Level for
Conference and Transfer Calls
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 16 (-8dB)]
14-01-13 Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
For each trunk, enter 1 to enable
loop supervision.
0 = Disable
1 = Enable
(default = 1)
15-07-01 Programmable Function Keys Assign a function key for Transfer
(code 06).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
20-07-11 Class of Service Options
(Administrator Level) – Forced
Trunk Disconnect (analog trunk
only)
Turns Off (0) or On (1) an
extension to use Forced Trunk
Disconnect. This allows the
extension to disconnect an
Unsupervised Conference in
progress.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-11-14 Class of Service Options (Hold/
Transfer Service) –
Trunk-to-Trunk Transfer
Restriction
Turns Off (0) or On (1) the
Trunk-to-Trunk Transfer
Restriction. If enabled,
Trunk-to-Trunk Transfer is not
possible.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-11-21 Class of Service Options (Hold/
Transfer Service) – Restriction
for Tandem Trunking on Hang Up
Deny (1) an extension user’s
ability to set up a tandem call
automatically when they hang up.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
Enables the extension Barge-In
Mode to be speech mode (0) or
Monitor mode (1).
0 = Off
1 = On
(default = 0 for
COS 1~15)