UNIVERGE SV8100 Issue 5.0
Tandem Trunking (Unsupervised Conference) 1 - 975
Method C – Tandem Trunking on Hang up
24-02-07 System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
This timer starts when a trunk
begins talking with another trunk
(for example: Trunk-to-Trunk
Transfer, outgoing from trunk,
Tandem Trunking).
0~64800 (seconds)
(default = 1800
seconds)
24-02-10 System Options for Transfer –
Disconnect Trunk-to-Trunk
This timer starts after the
Trunk-to-Trunk warning tone is
heard.
0~64800 (seconds)
(default = 0 seconds)
25-07-07 System Timers for VRS/DISA –
Long Conversation Warning
Tone Time
Determine the time a DISA caller
or any trunk-to-trunk (such as
Tandem Trunking) conversation
can talk before the Long
Conversation tone is heard.
0~64800 (seconds)
(default = 3600
seconds)
25-07-08 System Timers for VRS/DISA –
Long Conversation Disconnect
Time
Determine the time the system
waits before disconnecting a DISA
or any trunk-to-trunk (such as
Tandem Trunking) call after the
Long Conversation tone is heard.
0~64800 (seconds)
(default = 10 seconds)
Program
Number
Program Name Description/Comments Assigned Data
14-01-04 Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
14-01-05 Basic Trunk Data Setup –
Receive Gain Level for
Conference and Transfer Calls
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
1~63(-15.5dB ~
+15.5dB in 0.5dB
intervals)
[default = 16 (-8dB)]
14-01-13 Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
For each trunk, enter 1 to enable
loop supervision.
0 = Disable
1 = Enable
(default = 1)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
Program
Number
Program Name Description/Comments Assigned Data