75
Alarm
No.
Type
Name
Content of Alarm
Cause
Action
Recovery
55
Minor
Regular
maintenance
exchange
notification.
The regular
maintenance exchange
day has passed.
• The regular maintenance
exchange day that had been
set with PRG 90-51
exceeded it.
Please do the
maintenance
exchanges of pertinent
parts, and set the next
regular maintenance
exchange day with
PRG 90-51.
The excess on the
regular
maintenance
exchange day is
canceled by
changing PRG 90-
51 or when the
function is
invalidated, the
error is recovered.
56
Not set
--- Reserved ---
57
Minor
IP Address
Collision
1.Collision(01)
Minor.Collision(0Minor)
3.Collision(03)
4.Collision(04)
5.Collision(05)
6.Collision(06)
7.Collision(07)
8.Collision(08)
9.Collision(09)
10.Collision(10)
Collision with PRG10-
1Minor-01
Collision with PRG10-
1Minor-09
Collision with PRG84-
Minor6-01 GW1
Collision with PRG84-
Minor6-01 GWMinor
Collision with PRG84-
Minor6-01 GW3
Collision with PRG84-
Minor6-01 GW4
Collision with PRG84-
Minor6-01 GW5
Collision with PRG84-
Minor6-01 GW6
Collision with PRG84-
Minor6-01 GW7
Collision with PRG84-
Minor6-01 GW8
1.Change collided
address
Minor.Change collided
address
3.Change collided
address
4.Change collided
address
5.Change collided
address
6.Change collided
address
7.Change collided
address
8.Change collided
address
9.Change collided
address
10.Change collided
address
The error is
recovered when
collision is
corrected
58~59
Not set
--- Reserved ---
60
Minor
SIP Registration
Error
Notification.
1.The registration of the
SIP trunk to the SIP
server failed.
Minor.The registration
of the SIP trunk to the
SIP server failed in the
authentication.
3.There is no response
from the SIP server to
the SIP registration
request.
• The setting of the system
data is wrong.
• The setting of the router is
wrong.
• It is an error to the link of
LAN.
• Net side trouble.
1. Reconfirm the
following system data
setting -- PRG 10-
1Minor, 10-Minor8,
10-Minor9, 10-30, and
10-36.
Minor.Confirm the
setting of routers.
3.Confirm whether
abnormality occurs on
the net side.
4.Reconfirm the
authentication system
data setting.
5.Reconfirm wiring
and the system data
setting. Please inquire
an uncertain point of
the maker.
The error is
recovered when
normally
connecting it.