5.2.3 Relay / timing
Configure timing parameters.
Figure 13: Relay / timing settings
Setting 'Automatic relay activation' has no effect for uPASS Access.
The 'Tag hold time' setting is the time an identified tag is "held" in reader memory. The timer expires when the tag is no
longer identified. The timer is used for the automatic LED control and for sending a new identification event message.
The 'Vehicle hold time' setting is the time, after a vehicle-id tags has been found, for which the reader will search for
driver-id tags. This setting is only used in the NEDAP DUAL-ID mode.
The Random off time parameter can be used to enable time sharing between multiple readers on the same frequency.
Recommended to enable this setting.
Notes
The uPASS Access does not have a relay output.