uPASS Access | installation guide
7/
33
2 Installation
2.1 Safety instruction
The following safety precautions should be observed during normal use, service and repair.
The uPASS Access may only be installed and serviced by qualified service personnel.
Disconnect the power supply before (dis)connecting any wires, uPASS Access is NOT hot-swappable, so when
making or changing connections, power must be switched OFF.
The cable shield shall be connected with safety ground and the metal case of the external device(s).
To be sure of safety, do not modify or add anything to the uPASS Access other than mentioned in this installation
guide or indicated by NEDAP N.V.
2.2 Mounting instruction
The uPASS Access can be mounted to a stone, concrete or wooden wall. Metal may decrease the reading performance.
Nedap recommends to perform read tests when installing the reader on or near metal.
See the picture below for details about the installation dimensions.
Figure 1: uPASS Access dimensions